EC-2 – 7ftReturn to Products Page
Capacity | 2,000 lbs (907 kg) at 3.25 ft (1.0 m) | ||
Rating | 6,500 ft-lb (0.9 t-m) | ||
Length | 7 ft (2.13 m) fully extended | ||
Weight | 255 lb (115 kg) | ||
Chassis | Class 2 (5200 GVWR minimum) | ||
Body | Titan 16 | ||
Stowed Boom Length | 4′ 2½” – 7′ 1″ (1.28 m-2.16 m) | ||
Extended Boom Length | 7′ (2.13 m) | ||
Width | 12″ (.3 m) | ||
Height | 4′ 2½” – 7′ 1″ (1.28 m-2.16 m) | ||
Base Plate Dimensions | 12.0" x 12.0" (0.3 m x 0.3 m) | ||
Single Line Speed | 9 ft/min (no load) | ||
Motor | 12 volt DC, permanent magnet, ¾ hp hoist motor | ||
Cable | 25 ft (7.62 m) of ¼” (6.35 mm) aircraft quality cable (2) | ||
Warranty | 2 year warranty | ||
Resources |
EconoTon II Manual Service Cranes Sales Sheet |
Amperage Draw/Capacity
Current Draw
(amps)* |
Lifting Weight
(lb (kg)) |
Line Speed
(ft (m)/min) |
Single or Double Line to Block |
15 | No load | 9.1 (2.77) | Single |
25 | 500 (227) | 8.0 (2.44) | Single |
35 | 1,000 (454) | 7.1 (2.16) | Single |
70 | 2,000 (907) | 7.1 (2.16) | Single |
*12V system
Requirements
- Truck must be equipped with jackleg extending minimum 3′ 3″ (1 m) from center-line of truck
- 5,200 GVWR minimum chassis requirement. (Does not include bodies and accessories)
- Battery Information: 575 amp cold cranking rating, 130 minute reserve capacity, maintenance type battery required for 12 volt DC operation. 70 amp minimum truck alternator required
Configurations
- 3 ft, 4 ft or short pedestal
- Manual or power rotation
- 25 ft – 1/4″ 7×19 galvanized cable with hook (standard)